具有可变蒸汽扩散性和加强网格的薄膜
CLIMA CONTROL NET 160
CLIMA CONTROL NET 160是一种具有可变蒸汽扩散性的薄膜,可防止天气影响,在内部相对湿度过高时可透汽,并在内部湿度处于适当水平时用作蒸汽控制膜。它是提高建筑维护和现有结构修复解决方案能量性能的理想薄膜。
CLIMA CONTROL NET 160:呼吸膜与隔汽膜的单一解决方案
由于其特殊的组成和加强网格,CLIMA CONTROL NET 160膜不受码钉、钉子或行走引起的磨损造成的机械应力的影响。特殊的PA膜使产品能够适应建筑物的湿度条件。如果薄膜与高湿度接触,它将从蒸汽控制层转变为透汽产品,确保结构保持干燥。它是为环境保护署和生命周期评价环境声明所研制的产品之一。
文件
技术数据表
|
|
---|---|
符合性声明(DOC)
|
|
File BIM.rfa
|
|
Xml-File WUFI
|
|
施工步骤
|
|
Environmental Product Declaration (EPD) | 下载 |
Test Report
|
CLIMA CONTROL NET 160
CODE | description | tape | H
[m]
|
L
[m]
|
A
[m²]
|
H
[ft]
|
L
[ft]
|
A
[sft]
|
pcs./pallet |
---|---|---|---|---|---|---|---|---|---|
CLIMATT160 | CLIMA CONTROL NET 160 TT | TT | 1.5 | 50 | 75 | 4' 11'' | 164 | 807 | 25 |
Technical Data
属性 | 标准 | 数值经过测试 | USC 转换 |
---|---|---|---|
Mass per unit area | EN 1849-2 | 160 g/m² | 0.52 oz/ft² |
Thickness | EN 1849-2 | 0,5 mm | 20 mil |
Variable water vapour transmission (Sd) | EN 12572 | 0,5 / 5 m | 6.993 / 0.699 PERM |
Water vapour transmission (dry cup) | ASTM E96/ E96M | 2.68 PERM | - |
Water vapour transmission (dry cup) | ASTM E96/ E96M | 153 ng/(s·m²·Pa) | - |
Water vapour transmission (wet cup) | ASTM E96/ E96M | 7.91 PERM | - |
Water vapour transmission (wet cup) | ASTM E96/ E96M | 452 ng/(s·m²·Pa) | - |
Tensile strength MD/CD | EN 12311-2 | 400 / 270 N/50mm | 46 / 31 lb/in |
Elongation MD/CD | EN 12311-2 | 20 / 20 % | - |
Resistance to nail tearing MD/CD | EN 12310-1 | 240 / 250 N | 54 / 56 lbf |
Watertightness | EN 1928 | compliant | - |
Thermal resistance | - | -40 / 80 °C | -40 / 176 °F |
Reaction to fire | EN 13501-1 | class E | - |
Resistance to penetration of air | EN 12114 | 0 m³/(m²·h·50Pa) | 0 cfm/ft² at 50Pa |
Water vapour resistance - after artificial ageing | EN 1296 / EN 1931 | compliant | - |
Water vapour resistance - in the presence of alkalis | EN 1847 / EN 12311-2 | npd | - |
Thermal conductivity (λ) | - | 0,3 W/(m·K) | 2.08 (BTU·in)/(h·ft²·°F) |
Specific heat | - | 1800 J/(kg·K) | - |
Density | - | ca. 320 kg/m³ | - |
Variable water vapour resistance factor (μ) | - | ca. 1000 / 10000 | - |
VOC content | - | 0 % | - |
UV stability | EN 13859-2 | 3 months | - |
Exposure to weather | - | 4 weeks | - |
Water column | ISO 811 | > 250 cm | > 98.4252 in |
Composition
TOP LAYER | non-woven PP fabric |
---|---|
REINFORCING LAYER | PE reinforcing grid |
middle layer | PA functional film |
BOTTOM LAYER | non-woven PP fabric |